three wavelength laser hair elimination equipment

Shop the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG equipment features 3 wavelengths (755, 808, 1064nm) for painless hair elimination.
2-in-1 Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Device
Achieve Expert-grade final results With all the Soprano Titanium Ice Platinum, a powerful 2-in-one process combining 3-wavelength diode laser know-how for pain-free hair elimination as well as a Q-Switched ND:YAG laser for tattoo elimination and skin rejuvenation. Geared up which has a 4000W superior-ability motor and five-amount adjustable cooling technological know-how, this CE-Qualified device provides Safe and sound, productive, and long term results for all pores and skin kinds and body spots.

Hair Removing: Triple wavelength (755nm, 808nm, 1064nm) for all skin tones
Skin Correction: Q-Switched ND:YAG for tattoo removing and carbon peeling
Comfort and ease: 5-Level adjustable cooling procedure for your pain-free knowledge
Electricity: 4000W substantial-Power density with German Diode Arrays

Important Attributes
three-Wavelength Diode Technological know-how: Integrates 755nm (Alexandrite), 808nm (Pace), and 1064nm (YAG) wavelengths into an individual applicator to target various hair depths and structures simultaneously.
Twin-Purpose Method: A real 2-in-1 workstation that includes a devoted Diode laser for long term hair reduction and a Q-Switched ND:YAG laser for pigmented lesion procedure and tattoo elimination.
Innovative 5-Level Cooling: Options the “Titanium Ice” 5-amount adjustable cooling know-how that retains the sapphire tip at an best temperature, making certain the treatment continues to be relaxed and painless.
Superior Output Effectiveness: Driven by a large 4000W electricity supply and German-imported Diode arrays, offering up to 2000mj Electrical power density for rapidly and efficient scientific benefits.
Big Touchscreen Interface: Geared up using a significant-definition interactive Show for specific Handle over Electricity amounts, pulse frequency, and cooling depth across diverse therapy modes.
Compatibility & Finest Use
Complete System Application: Protected and productive for use around the confront (higher lip, chin), underarms, bikini line, arms, legs, back, and upper body.
All Pores and skin Types: The triple wavelength technique is meant to perform correctly on all pores and skin tones (Fitzpatrick scales I-VI) and hair colours, which include good and light-weight hair.
Pores and skin Rejuvenation: Utilize the ND:YAG manage Together with the black doll (carbon) idea for deep pore cleansing, skin whitening, and anti-growing older solutions.
Tattoo & Pigment Removing: Target darkish and coloured click here inks exclusively utilizing the Q-Swap frequency for non-invasive removal of tattoos and freckles.
Installation Guidelines
H2o Cooling Set up: This high-electrical power laser calls for distilled drinking click here water for its cooling process; make sure the h2o tank is filled website to the suggested degree ahead of powering to the equipment for The 1st time.
Handle Relationship: Carefully align the pins from the laser handles With all more info the device ports and secure the locking mechanism to ensure stable sign and cooling fluid transmission.
Voltage Verification: The equipment supports 110V and 220V; ensure your ability outlet matches the precise voltage configurations of your equipment to forestall electrical problems.
Parameter Calibration: For brand new end users, it is suggested to begin remedies at the lowest energy configurations and slowly enhance depending on the client’s skin sensitivity and feed-back.
Products Specs
Brand name Name emszero
Product Variety Titanium 2-in-one (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Ability Output 4000W
Electricity Density Approximately 2000mj (Adjustable)
Cooling Degree 5 Concentrations Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, 50/60Hz
Packing List
one x Soprano Titanium 2-in-one Principal Console (4000W)
1 x three-Wavelength Diode Laser Take care of
1 x Q-Swap ND:YAG Laser Take care of
3 x Specialised ND:YAG Guidelines (532nm, 1064nm, 1320nm)
1 x Ability Cable & Foot Pedal
one x User Handbook & Protective Goggles Established

Warnings & Basic safety Notes
Eye Security: Always have on the presented laser-security goggles during Procedure to stop permanent eye problems from stray laser reflections.
In no way Run Dry: Will not operate the equipment without having filling it with distilled water; jogging the laser with no performing cooling loop will cause instant interior hardware failure.
Contraindications: Will not use this unit on spots with open wounds, Lively infections, or on people who are pregnant or have light-weight-sensitive clinical circumstances.
Cooling Routine maintenance: Change the distilled drinking water each three months to make sure The interior pump and Mainland China laser arrays remain free of mineral buildup and overheating.

Leave a Reply